Infrared heating for garden seating areas

Focus warmth on the part of your garden where people sit, such as a pergola, gazebo or covered seating area.

Garden with a dedicated outdoor seating area

Plan your installation

Start with the seating zone and the structure available for mounting. Wind, rain exposure and the position of nearby materials affect the choice of configuration and installation.

Send a photo, seating area dimensions and details of the pergola, gazebo or other mounting structure.

EU stock · Ask us about availability for your configuration.

Planning examples

A pergola within a larger garden

In a 10 × 12 m garden, the example focuses on a 4 × 4 m pergola seating zone. It does not propose heating the whole garden.

Whole space10 × 12 m120 m²
Selected zone4 × 4 m16 m²
Assumed mounting height2.5 m

Assumptions for this example. A sheltered seating area with a suitable mounting structure at 2.5 m. Wind exposure and distances from plants and surrounding materials need to be assessed.

Illustrative layouts, not completed installation references. Choose a configuration to explore a starting point for your project.

2 × BH-1500Total connected load: 3 kW
10 m 12 m 1 2
Selected zone; not a radiation footprint · 16 m²Proposed heater positions
Heaters in this example
2 × BH-1500
Total connected load
3 kW
Catalogue area per heater
8–16 m²
Rated supply
235 V AC
Catalogue mounting range
1.3–2.5 m

How the quantity is estimated

16 m² ÷ 8 m² = 2 → 2 × BH-1500

Selected zone divided by the lower end of the catalogue area range, rounded up to a whole heater.

View model specifications ↗
2 × RCH-2000/6Total connected load: 4 kW
10 m 12 m 1 2
Selected zone; not a radiation footprint · 16 m²Proposed heater positions
Heaters in this example
2 × RCH-2000/6
Total connected load
4 kW
Catalogue area per heater
10–20 m²
Rated supply
235 V AC
Catalogue mounting range
1.5–3 m

How the quantity is estimated

16 m² ÷ 10 m² = 1.6 → 2 × RCH-2000/6

Selected zone divided by the lower end of the catalogue area range, rounded up to a whole heater.

View model specifications ↗

A starting point for your project. Catalogue area is a reference value. Air temperature, wind, insulation and mounting affect the required output. This is a starting point for an enquiry, not a heat-loss calculation or a guarantee of comfort.

Positions are illustrative. Quantity, aiming, spacing and installation clearances must be confirmed for the actual site. Connected load is the sum of rated powers, not daily energy consumption.

Explore product series

Final selection depends on site conditions and the installation instructions for the selected model.

Search the Elcon catalogue